Windows Free Downloads

Double Pipe Heat Exchanger Design (DHex) 1.0 Icon  Double Pipe Heat Exchanger Design (DHex) 1.0

"step by step thermal design calculations"

 
Popularity: Popularity: 100.0% 100.0%
User Ratings: User ratings: 5.0 of 5.0 (based on 1 votes) 1 vote
Your Rating:
Bookmark: Bookmark and Share
Double Pipe Heat Exchanger Design (DHex) 1.0 Screenshot
 
Downloads: Total: 192  |  Last 7 days: 21
Publisher: WeBBusterZ Engineering Software  |  View 2 other products
OS: Windows 98/ME/XP/Vista  
Release Status: New Release 
Install Support: Install and Uninstall 
License: Demo  | $59.99 to buy
Size: 5.99 MB
Release Date: 3/18/2006
Date Added: 5/18/2007
Last Update: 5/6/2008
Free Download Double Pipe Heat Exchanger Design (DHex) 1.0       Buy Double Pipe Heat Exchanger Design (DHex) 1.0
 
Double Pipe Heat Exchanger Design (DHex) Publisher's Description
DHex is a software tool that is made to demonstrate the chemical design calculations of Double pipe (hairpin) Heat Exchangers.The software will do all the thermal calculations involved in the design and will generate a summary of all results, List of main functions:
+Step by step calculation
+Support S.I Units and English (U.S) Units of mesurement.
+User database functions to allow user to add/delete components and load to hot/cold side (Empty database!).
+Ability to import properties to Hot/Cold sides from Microsoft Excel.
+Ability to calculate unknown Cold or Hot side temperatures.
+Perform thermal analysis for bare tube double pipe (hairpin) heat exchangers.+Perform thermal analysis for finned tube double pipe (hairpin) heat exchangers.
+Choose from Counter Current or Co-Current Flow arrangement.
+Choose from Series arrangement or Series-Parallel arrangement.
+The software will also tell you the location of Hot/Cold fluids within the heat exchanger (Inner Pipe or Outer Pipe).
+Select from different correlations to calculate Cold/Hot side heat transfer coefficient. Also the ability to adjust Nusselt number if you do have a different correlation.
+Calculate the Area, Flow area, Length, Log Mean Temperature Differance, Number of Hairpins,Unknown Flow rate.
+Calculate the scale resistance (dirt factor), Equivalent Diameter.
+Calculate Pipe/Annulus side Reynolds, Nusselt numbers & Prandtl Numbers
+Duty Calculation, Clean and Design Overall heat transfer coefficient calculations.
+Pipe/Annulus velocities and Mass velocity calculations
+Number of Transfer Units and Thermal Capacity ratio calculation +Clean and Fouled Fin Efficiency calculations for finned tube heat exchanger.
+Pressure drop calculations & Entrance and Exit losses.
+Export Results summary to Microsoft Excel
+Save/Load results. Generate/Print a summary of results. For more information visit http://www.webbusterz.com or http://www.webbusterz.net. Now, go ahead and free download Double Pipe Heat Exchanger Design (DHex).
System Requirements
Windows operating system, 20MB Free space
Related Tags
heat exchanger , double pipe , hairpin heat exchangers , thermal design calculations , double pipe heat exchanger design (dhex) , business , math & scientific tools
Do not use cracks, passwords, serial numbers, registration codes, and key generators, because they are illegal and they prevents further software development. If you like and need this software, you should buy it.
 
Free Newsletter
Google Search